Instantor Pocket-PRO™

Instantor Pocket-PRO™

The Pocket Routed XPS Panel system is a quick, easy to install panel intended for use in overlay applications. Designed to increase system performance over traditional overlay panel systems, the panels include pockets routed into the XPS panel which allow levelling compound to more efficiently enclose the pipe, increasing overall system performance by up to 20%.
This system can only be covered with levelling compound.

After installation of all pipework and pressure testing, the panels should be primed before a minimum of 6mm of levelling compound is applied to the surface. For LVT floor coverings it is recommended that a minimum of 10mm of levelling compound is applied.

Due to the increased level in system performance, this UFH system compliments the use of low temperature heat sources.

Warranty
Pex-Al-Pex: 50 Years,  Pert-Evoh-Pert: 50 Years, Manifold: 5 Years, Mixing Kit: 5 Years, Pump: 5 Years, Whisper Controls: 5 Years

Key Features

Quick & easy to install

Suitable for use with low temperature heating systems

Ultra-High Heat Output due to Pockets increasing system performance

Lightweight & easy to cut/trim

Low Profile Floor Build-Up

Can be laid over Solid or Timber Floors

400kPa Compressive Strength allows for increased structural integrity

Omega pipe channels ensuring pipe stays in place when under tension

Easy management of connection pipes with flow and return pathways integrated into the panel

Available Options

Pipe Types
Available
16mm PEX-AL-PEX
16mm 5-Layer PE-RT/EVOH

Typical Pipe
Spacings (mm)
150mm

Pipework Layout Suitability

Floor Covering Suitability


Seek advice from floor covering manufacturer regarding installation methods prior to installation

Heat Output

Watts per m² at 150mm Pipe Centres

Pipe Spacing 150mm
Design Room Temperature 20°C
UFH Pipe Circuit ΔT 5°C
Floor Covering
Resistance (TOG)
Flow Temperature (°C)
30 35 40 45 50
0.00 53 88
0.50 38 63 88 113
1.00 44 61 79 96
1.50 47 61 74
2.00 40 52 63
2.50 43 52

 

Pipe Spacing 150mm
Design Room Temperature 20°C
UFH Pipe Circuit ΔT 7°C
Floor Covering
Resistance (TOG)
Flow Temperature (°C)
30 35 40 45 50
0.00 46 81 116
0.50 58 83 108
1.00 40 58 75 93
1.50 45 58 72
2.00 38 49 61
2.50 41 50