Instantor Pocket-PRO™
Instantor Pocket-PRO™
The Pocket Routed XPS Panel system is a quick, easy to install panel intended for use in overlay applications. Designed to increase system performance over traditional overlay panel systems, the panels include pockets routed into the XPS panel which allow levelling compound to more efficiently enclose the pipe, increasing overall system performance by up to 20%.
This system can only be covered with levelling compound.
After installation of all pipework and pressure testing, the panels should be primed before a minimum of 6mm of levelling compound is applied to the surface. For LVT floor coverings it is recommended that a minimum of 10mm of levelling compound is applied.
Due to the increased level in system performance, this UFH system compliments the use of low temperature heat sources.
Warranty
Pex-Al-Pex: 50 Years, Pert-Evoh-Pert: 50 Years, Manifold: 5 Years, Mixing Kit: 5 Years, Pump: 5 Years, Whisper Controls: 5 Years
Key Features
Quick & easy to install
Suitable for use with low temperature heating systems
Ultra-High Heat Output due to Pockets increasing system performance
Lightweight & easy to cut/trim
Low Profile Floor Build-Up
Can be laid over Solid or Timber Floors
400kPa Compressive Strength allows for increased structural integrity
Omega pipe channels ensuring pipe stays in place when under tension
Easy management of connection pipes with flow and return pathways integrated into the panel
Available Options
|
Pipe Types Available |
16mm PEX-AL-PEX 16mm 5-Layer PE-RT/EVOH |
|
Typical Pipe Spacings (mm) |
150mm |
Pipework Layout Suitability

Floor Covering Suitability

Seek advice from floor covering manufacturer regarding installation methods prior to installation
Heat Output
Watts per m² at 150mm Pipe Centres
| Pipe Spacing | 150mm | ||||
| Design Room Temperature | 20°C | ||||
| UFH Pipe Circuit ΔT | 5°C | ||||
| Floor Covering Resistance (TOG) |
Flow Temperature (°C) | ||||
| 30 | 35 | 40 | 45 | 50 | |
| 0.00 | 53 | 88 | – | – | – |
| 0.50 | 38 | 63 | 88 | 113 | – |
| 1.00 | – | 44 | 61 | 79 | 96 |
| 1.50 | – | – | 47 | 61 | 74 |
| 2.00 | – | – | 40 | 52 | 63 |
| 2.50 | – | – | – | 43 | 52 |
| Pipe Spacing | 150mm | ||||
| Design Room Temperature | 20°C | ||||
| UFH Pipe Circuit ΔT | 7°C | ||||
| Floor Covering Resistance (TOG) |
Flow Temperature (°C) | ||||
| 30 | 35 | 40 | 45 | 50 | |
| 0.00 | 46 | 81 | 116 | – | – |
| 0.50 | – | 58 | 83 | 108 | – |
| 1.00 | – | 40 | 58 | 75 | 93 |
| 1.50 | – | – | 45 | 58 | 72 |
| 2.00 | – | – | 38 | 49 | 61 |
| 2.50 | – | – | – | 41 | 50 |